Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — HSS PUMP

SEN00285-01 10 Structure, function and maintenance standard (2) Operation in the direction for maximum pump discharge amount q When the difference between main pump pres- sure (PP) and LS pressure (PLS), in other words, LS differential pressure ( d PLS) becomes smaller [for example, when the area of opening of the control valve becomes larger and pump pressure (PP) drops], spool (4) is pushed to the right by the combined force of LS pressure (PLS) and the force of spring (3). q When spool (4) moves, port (b) and port (c) are joined and connected to the TVC valve. q TVC valve is connected to the drain port, so the pressure of circuit (c) – (h) becomes drain pressure (PT).

[The operation of TVC valve is explained later.] q The pressure at the large piston diameter end of servo piston (1) becomes drain pressure (PT), and pump pressure (PP) enters the small diameter end, so servo piston (1) is pushed to the right. q Rod (2) moves to the right and moves the swash plate in the direction to make the dis- charge amount larger. 20 D65EX, PX, WX-15E0