10 Structure, function and maintenance standard SEN00285-01 (3) Operation in the direction for minimum pump discharge amount q The following explains the situation if servo piston (1) moves to the left [the discharge amount becomes smaller]. q When LS differential pressure ( d PLS) becomes larger [for example, when the area of opening of the control valve becomes smaller and pump pressure (PP) rises], pump pressure (PP) pushes spool (4) to the left. q When spool (4) moves, main pump pressure (PP) flows from port (d) to port (c), and from port (h), it enters the large piston diameter end.
q Main pump pressure (PP) also enters the small piston diameter end, but because of the differ- ence in area between the large and the small piston diameter ends of servo piston (1), servo piston (1) is pushed to the left. q Rod (2) moves in the direction to make the swash plate angle smaller. D65EX, PX, WX-15E0 21