Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — HSS PUMP

SEN00285-01 10 Structure, function and maintenance standard (4) When servo piston is balanced q Let us take the area receiving the pressure at the large diameter end of the piston as (A1), the area receiving the pressure at the small diameter end as (A0), and the pressure flowing into the large diameter end of the piston as (PEN). q The position where spool (4) is balanced and stopped is the standard center, and the force of spring (3) is adjusted so that it is determined when (PP) – (PLS) = 1.96 MPa {20 kg/cm 2 }. q If main pump pressure (PP) of the LS valve and the combined force of force (F) of spring (3) and LS pressure (PLS) are balanced, the relationship is (A0) Ч (PP) = (A1) Ч (PEN).

q Servo piston (1) stops in that position, and the swash plate is kept at an intermediate position. [It stops at the position where the opening from port (b) to port (c) and from port (d) to port (c) of spool (4) is approximately the same.] q The relationship between the area receiving the pressure at both ends of piston (1) is (A0) : (A1) = 1 : 2, so the pressure applied to both ends of the piston when it is balanced becomes (PP) : (PEN) C 2 : 1. 22 D65EX, PX, WX-15E0