Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — HSS PUMP

10 Structure, function and maintenance standard SEN00285-01 2. TVC valve (1) When the transmission and steering controller is normal 1) When the load on the actuator is small and pump pressure (PP) is low a. Operation of solenoid (1) q Command current (X) from the transmission and steering controller flows to solenoid (1). This command current (X) changes the internal force pushing solenoid push pin (11). q On the opposite side to the force pushing this solenoid push pin (11) is the spring set pres- sure of springs (3), (4) and pump pressure (PP). Piston (2) stops at a position where the combined force pushing piston (2) is balanced.

q The pressure output from TVC valve [pressure of port (c)] changes according to this position. q The size of command current (X) is determined by the nature of the operation (lever opera- tion), the selected working mode, and the set value and actual value of the engine speed. D65EX, PX, WX-15E0 23