Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — HSS PUMP

10 Structure, function and maintenance standard SEN00285-01 2) When the load on actuator is small and the pump discharge pressure is high q When the load is large and pump discharge pressure (PP) is high, the force pushing piston (2) to the left becomes larger and piston (2) moves to the position shown in the diagram above. q Springs (3) and (4) are compressed and push back piston (2). Because of this force, piston (2) cuts of the connection from port (b) to port (c), and port (c) and port (d) are connected.

q As shown in the diagram above, part of the pressurized oil from port (b) flows out to port (d) and the pressure oil flowing from port (c) to the LS valve becomes approximately half of main pump pressure (PP). q As a result, the pressure at port (c) [= (f)] drops, and piston (9) stops moving to the left. q The position in which piston (9) stops when this happens is further to the left than the posi- tion when pump pressure (PP) is low. q When port (h) and port (e) of LS valve are con- nected [see “1. LS valve“], the pressure from port (f) enters the large piston diameter end of servo piston (9), and servo piston (9) stops.

q If main pump pressure (PP) increases further and piston (2) moves further to the left, main pump pressure (PP) flows to port (c) and acts to make the discharge amount the minimum. q When piston (9) moves to the left, piston (5) is moved to the right by cam (7) and lever (6). D65EX, PX, WX-15E0 25