SEN00285-01 10 Structure, function and maintenance standard 2. Safety valve Function q When the operation of the steering stops, counterbalance valve (10) closes the circuit at the inlet and outlet ports of the HSS motor. q But the HSS motor continues to turn because of inertia. As a result, the pressure at the out- let port of the HSS motor becomes extremely high, and this will damage the HSS motor and the piping. q The safety valve acts to release this abnormal pressure to the inlet port of the HSS motor to protect the equipment from damage.
q When the operation of the steering is stopped, the check valve of the counterbalance valve (10) closes chamber (E) (or chamber (F)) in the outlet port circuit, but the pressure at the outlet port side continues to rise because of inertia. Operation q If the pressure in chamber (E) (or chamber (F)) goes above the set pressure, the force of x /4 (D1 2 – D2 2 ) Ч pressure resulting from the differ- ence in area of (D1) and (D2) (or the force of x / 4 (D3 2 – D1 2 ) Ч pressure resulting from the dif- ference in area of (D3) and (D1)) becomes greater than the force of the spring and moves the poppet to the right.
The oil then flows to chamber (F) (or chamber (E)) in the circuit on the opposite side. 34 D65EX, PX, WX-15E0