Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — CONTROL VALVE

SEN00286-01 10 Structure, function and maintenance standard Operation of control valve At “hold“ (operation of unload valve) Function q When the main spool is at the “hold“ position, it drains the excess oil discharged by the pump, and prevents the pressure from being formed in the circuit from rising. Operation q When the main spool is at the “hold“ position, the pump pressure passes from chamber (A) through throttle (4) to chamber (D). Chambers (C) and (C') are connected to the drain circuit.

q When the oil is supplied from the pump, the pressure in chamber (D) rises, and spool (1) is pushed to the right by pressure which is deter- mined by the cross-sectional area of piston (3) receiving the pressure. q When the received pressure becomes larger than set load of spring (2), the spool moves to the right and connects the passage between chamber (A) and chamber (B), so the oil from the pump is drained. q Therefore, spool (1) is balanced at a position that matches the supply of oil from the pump. Actually, the amount of oil supplied from the pump is small, so the pressure in the circuit is almost the same as the set load of spring (2). 14 D65EX, PX, WX-15E0