10 Structure, function and maintenance standard SEN00286-01 Control of oil flow Function q Use of the CLSS circuit (Closed center Load Sensing System) makes it possible to control the oil flow by adjusting the area of opening of the spool driven by the EPC valve regardless of the load. 1. Steering valve 1) At “hold“ Operation q Chamber (G) is drained through chamber (H) to chamber (F). When this happens, the pump pressure is acting on the left end of spool (3) of the steering priority valve, so it pushes against the load of spring (4) and moves to the right to the maximum stroke position.
q When the spool is at the “hold“ position, the pump pressure is sent from chamber (A) through the notch in spool (3) of the steering priority valve, and passes through chamber (B) to chamber (C). q In this condition, the area of the opening to spool (1) of the steering valve is at its mini- mum. D65EX, PX, WX-15E0 15