Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — CONTROL VALVE

SEN00286-01 10 Structure, function and maintenance standard 2) When turning to the left q d PLS = Differential pressure between ports (K) and (J) = 2.0 MPa {20 kg/cm 2 } q Chamber (C) and chamber (D) are connected, and the oil from the pump flows through ports (A), (B), (C) and (D) to HSS motor (6). q d PLS' = Differential pressure between ports (I) and (D) q At the same time, the load pressure in cham- ber (D) passes through LS orifice (5) and chamber (H), and is sent to chamber (G). It is also sent from LS circuit (O) to pump servo valve (7).

q d PLS C d PLS' Operation q When the steering lever is operated to turn the machine to the “left”, pilot pressure (PI) acts on the right end of spool (1) through the EPC valve. q The condition of the pressure of spool (3) is chamber (B) pressure C chamber (C) pressure, and chamber (G) pressure C chamber (D) pressure, so spool (3) is controlled by the dif- ferential pressure of spool (1) (chamber (C) pressure – chamber (D) pressure), and bal- ances with spring (4). q When the pressure becomes greater than the set load of spring (2), spool (1) moves to the left. It becomes balanced at a position that matches pilot pressure (PI). 16 D65EX, PX, WX-15E0