Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — SELF PRESSURE REDUCING VALVE

SEN00286-01 10 Structure, function and maintenance standard No. Remedy Unit: mm 11 12 Replace spring if damaged or deformed. 13 14 Function q The self pressure reducing valves reduce the discharge pressure of the fan pump and sup- plies it to the PPC valve, EPC valve, etc. as the control pressure.

38 D65EX, PX, WX-15E0 Check item Criteria F Spring ou (pressure reducing valve main) Standard size Repair limit ree length × ter diameter Installation length Installation load Free length Installation load 19.2 × 7.20 16.1 19.6 N {2.0 kg} — 17.7 N {1.80 kg} Spring (pressure reducing valve pilot) 17.8 × 7.20 12.1 31.4 N {3.2 kg} — 28.4 N {2.9 kg} Spring 71.0 × 18.0 59.0 200 N {20.4 kg} — 186 N {19.0 kg} Spring (safety valve) 16.1 × 7.80 13.4 61.7 N {6.30 kg} — 58.8 N {6.0 kg}