Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — SELF PRESSURE REDUCING VALVE

10 Structure, function and maintenance standard SEN00286-01 Operation At engine stop (total low pressure) q Spring (6) pushes poppet (5) to the seat, and the circuit between ports (PR) and (T) is closed. q Spring (7) pushes valve (8) to the left side, and the circuit between ports (P1) and (PR) is open. q Spring (3) pushes valve (2) to the upper side, and the circuit between ports (P1) and (P2) is closed. D65EX, PX, WX-15E0 39