SEN00286-01 10 Structure, function and maintenance standard In the case of abnormal high pressure q When pressure (PR) of the self pressure reducing valve rises abnormally high, ball (10) will separate from the seat against spring (9) force to flow the hydraulic oil to output ports (PR) o (T) so as to reduce pressure (PR). As a result, the equipment [PPC valve, EPC valve, etc.], to which the oil pressure is sup- plied, is protected from the abnormal high pressure. 42 D65EX, PX, WX-15E0