Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — SELF PRESSURE REDUCING VALVE

10 Structure, function and maintenance standard SEN00286-01 At raise of load pressure (P2) q When load pressure (P2) rises due to digging or other operations, pump delivery increases and pressure (P1) rises. Then the expression [pressure (P1) > Spring (3) force + (area (d) Ч pressure (PR))] will hold, and valve (2) will move to the below side till the stroke end. As a result, the opening between ports (P1) and (P2) increases and passage resistance becomes smaller, reducing engine horsepower loss.

q When pressure (PR) rises above set pressure, poppet (5) opens and hydraulic oil flows through the route, from port (PR), through hole (a) in spool (8), through poppet (5) opening to the tank port (T). q Therefore, differential pressure occurs around hole (a) in spool (8) and spool (8) moves from port (P1) in the direction to close opening (PR). Then pressure (P1) is reduced and adjusted to a certain pressure [set pressure] with the opening and is supplied as pressure (PR). D65EX, PX, WX-15E0 41