Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — PPC VALVE (BLADE LIFT, BLADE TILT)

10 Structure, function and maintenance standard SEN00287-01 2. During fine control (Neutral o fine control) q When piston (4) is pushed by disc (5), retainer (9) is pushed, spool (1) is also pushed by metering spring (2), and moves down. q By this move, fine control hole (f) is shut off from drain chamber (D) and almost simulta- neously it is connected to pump pressure chamber (PP). The pilot pressure oil passes through fine control hole (f) and is conducted from port (P1) to port (PA3). q When the pressure at port (P1) becomes higher, spool (1) is pushed back and fine con- trol hole (f) is shut off from pump pressure chamber (PP).

At almost the same time, it is connected to drain chamber (D) to release the pressure at port (P1). q As a result, spool (1) moves up and down so that the force of metering spring (2) is bal- anced with the pressure at port (P1). The rela- tion between the positions of spool (1) and body (10) [fine control hole (f) is at the midpoint between drain chamber (D) and pump pres- sure chamber (PP)] does not change until retainer (9) contacts spool (1). q Therefore, metering spring (2) is compressed in proportion to the strokes of the control lever. Thus, the pressure at port (P1) increases in proportion to the strokes of the control lever.

q The control valve spool moves to a position where the pressure in chamber (PA3) [same as pressure at port (P1)] is balanced with the force of the return spring. D65EX, PX, WX-15E0 5