Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — PPC VALVE (BLADE LIFT, BLADE TILT)

SEN00287-01 10 Structure, function and maintenance standard 3. During fine control (when control lever is returned) 4. During full stroke q When disc (5) pushes down piston (4) and retainer (9) pushes down spool (1), fine control hole (f) is shut off from drain chamber (D) and is connected to pump pressure chamber (PP). q When disc (5) starts to be returned, spool (1) is pushed up by the force of centering spring (3) and the pressure at port (P1). q Because of this, fine control hole (f) is con- nected to drain chamber (D), and the pressur- ized oil at port (P1) is released.

q Therefore, the pilot pressure oil passes through fine control hole (f), is taken from port (P1) to chamber (PA3), and pushes the control valve spool. q If the pressure at port (P1) goes down too far, spool (1) is pushed down by metering spring (2). Fine control hole (f) is shut off from drain chamber (D), and almost simultaneously, it is connected to pump pressure chamber (PP). Pump pressure is supplied until the pressure at port (P1) recovers to a pressure equivalent to the position of the lever. q The return oil from chamber (PB3) passes from port (P2) through fine control hole (f'), and then flows to drain chamber (D).

q When the control valve spool returns, the oil at drain chamber (D) flows in from fine control hole (f') in the valve on the side that is not mov- ing. Oil passes through port (P2), is taken to chamber (PB3), and fills the chamber. 6 D65EX, PX, WX-15E0