SEN00287-01 10 Structure, function and maintenance standard Operation 1. At Neutral q Ports (A) and (B) of the control valve and ports (P1) and (P2) of the PPC valve are connected to drain chamber (D) via fine control hole (f) in spool (1). q The relation between the positions of spool (1) and body (8) [fine control hole (f) is at the mid- point between drain chamber (D) and pump pressure chamber (PP)] does not change until retainer (7) contacts spool (1). q Therefore, metering spring (2) is compressed in proportion to the strokes of the control lever. Thus, the pressure at port (P1) increases in proportion to the strokes of the control lever.
q In this way, the control valve spool moves to a position where the pressure of chamber (A) [same as pressure at port (P1)] and the force of the return spring of the control valve spool are balanced. 2. During fine control (Neutral o fine control) q As piston (4) is pushed by lever (5), retainer (7) is pushed too. At the same time, spool (1) is also pushed down via metering spring (2). q By this move, fine control hole (f) is shut off from drain chamber (D) and almost simulta- neously, it is connected to pump pressure chamber (PP). The pilot pressure oil passes through fine control hole (f) and is conducted from port (P1) to port (A).
q When the pressure at port (P1) becomes higher, spool (1) is pushed back and fine con- trol hole (f) is shut off from pump pressure chamber (PP). At almost the same time, it is connected to drain chamber (D) to release the pressure at port (P1). q As a result, spool (1) moves up and down until the force of metering spring (2) is balanced with the pressure at port (P1). 10 D65EX, PX, WX-15E0