Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — PPC VALVE (RIPPER)

10 Structure, function and maintenance standard SEN00287-01 3. During fine control (when control lever is returned) 4. During full stroke q When lever (5) pushes down piston (4) and retainer (7) pushes down spool (1), fine control hole (f) is shut off from drain chamber (D) and is connected to pump pressure chamber (PP). q When lever (5) starts to be returned, spool (1) is pushed up by the force of centering spring (3) and the pressure at port (P1). Because of this, fine control hole (f) is connected to drain chamber (D), and the pressurized oil at port (P1) is released.

q Therefore, the pilot pressure oil passes through fine control hole (f), is taken from port (P1) to chamber (A), and pushes the control valve spool. q If the pressure at port (P1) goes down too far, spool (1) is pushed down by metering spring (2). Fine control hole (f) is shut off from drain chamber (D), and almost simultaneously, it is connected to pump pressure chamber (PP). Pump pressure is supplied until the pressure at port (P1) recovers to a pressure equivalent to the position of the lever. q The oil returning from chamber (B) passes from port (P2) through fine control hole (f') and flows to drain chamber (D).

q When the spool of the control valve returns, the oil in drain chamber (D) flows in from fine control hole (f') in the valve on the side that is not working. The oil passes through port (P2) and enters chamber (B) to replenish the cham- ber with pressurized oil. D65EX, PX, WX-15E0 11