Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — MEASURING EXHAUST TEMPERATURE

30 Testing and adjusting SEN00585-00 Measuring exhaust temperature 1 a Measuring instrument for exhaust temperature k Install and remove the measuring instru- ment after the exhaust manifold is cooled. a Measure the exhaust temperature under the following condition. q Coolant temperature: Within operating range q Hydraulic oil temperature: Within operat- ing range q Power train oil temperature: Within operat- ing range 4. Procedure for measuring periodically for pre- ventive maintenance a If the torque converter is stalled simply, the torque converter oil temperature is overheated before the exhaust tempera- ture is stabilized. Accordingly, measure according to the following procedure.

1) Stall the torque converter fully to raise the exhaust temperature to about 450°C according to the following procedure (con- dition ( a ) in the figure). 1] Start the engine and set the fuel con- trol dial to the idle position, and then extract the blade tilt cylinder to the stroke end with the blade control lever. 2] With the brake pedal depressed securely, set the PCCS lever in the “forward” and 3rd gear speed posi- tion. 3] Press the decelerator pedal and set the fuel control dial in the high idle position. 4] Return the decelerator pedal slowly to allow the torque converter to stall at high idle and relieve the blade tilt cir- cuit. 1.

Open the right inspection cover of the engine and remove exhaust temperature pickup plug (1). 2. Install sensor [1] and connect them to digital temperature gauge B . a Clamp the wiring harness of the digital temperature gauge so that it will not touch a hot part during measurement. 3. Procedure for measuring the maximum value for troubleshooting Operate the machine actually and measure the maximum exhaust temperature. a Use the PEAK mode of the digital ther- mometer. a The exhaust temperature largely depends on the ambient temperature (intake air temperature of the engine). Accordingly, if any abnormal value is obtained, compen- sate it by the following calculation.

k Keep pressing the brake pedal securely and keep your right foot on the decelerator pedal for safety until the work is finished. q Corrected value [°C] = Measured value + 2 x (20 – Ambient tempera- ture) D65EX, PX, WX-15E0 9 Symbol Part No. Part name B 799-101-1502 Digital temperature gauge