SEN00585-00 30 Testing and adjusting 2) Stop only relieving the blade tilt and lower the exhaust temperature by only stalling the torque converter (condition ( b ) in the figure). a If the temperature does not lower but it rises, set the higher temperature in step 1). 3) After the temperature lowers and is stabi- lized, measure it (condition ( c ) in the fig- ure). k Just after the power train oil tem- perature gauge reads the red range, return the direction of the PCCS lever into neutral and lower the power train oil temperature. 5. After finishing measurement, remove the mea- suring instrument and reinstall the removed parts. 10 D65EX, PX, WX-15E0