Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — TESTING FUEL PRESSURE

SEN00585-00 30 Testing and adjusting 5. Testing fuel low-pressure circuit pressure (fuel filter outlet side) 1) Remove fuel pressure pickup plug (4) from the fuel main filter outlet side. 4) After finishing testing, remove the testing tools and return the removed parts. q Fuel pressure pickup plug: 20 – 22 Nm {2.0 – 2.2 kgm} 6. Testing drop of fuel low-pressure circuit pressure 1) Remove fuel pressure pickup plug (3) from the fuel main filter inlet side and fuel pressure pickup plug (4) from the outlet side. 2) Install adapter H2 and nipple [1] of hydraulic tester H1 to plug hole, and con- nect hydraulic tester H3 .

2) Install adapter H2 and nipple [1] of hydraulic tester H1 to plug hole, and con- nect hydraulic tester H3 . 3) Run the engine at high idle and measure the fuel low-pressure circuit pressure. a If the fuel low-pressure circuit pres- sure (at the fuel filter outlet side) is in the following range, it is normal. q Standard value of fuel low-pressure circuit pressure (fuel filter outlet side): Min. 0.48 MPa {Min. 4.9 kg/cm 2 } 3) Run the engine at high idle and measure the drop of the fuel low-pressure circuit pressure.

q Drop of fuel low-pressure circuit pres- sure = Fuel filter inlet pressure – Fuel filter outlet pressure a If the drop of fuel low-pressure circuit pressure is in the following range, it is normal. q Standard value of drop of fuel low- pressure circuit pressure: Max. 0.14 MPa {Max. 1.4 kg/cm 2 } 24 D65EX, PX, WX-15E0