SEN00585-00 30 Testing and adjusting Adjusting play of work equipment PPC valve 1 a The ripper valve is not adjustable. a If the end play of the blade lever is excessive, adjust it with their PPC valves according to the following procedure. q Standard play ( a ): 0.5 – 3.0 mm at 200 mm from revolution center of lever (in both longitudinal and lateral direc- tions) 1. Remove boot (1). 2. Loosen locknut (2) and turn disc (3) to adjust the play. a Do not move the piston at this time. 3. Fix disc (3) and tighten locknut (2). 3 Locknut: 98 – 127 Nm {10 – 13 kgm} 4. Install boot (1). 54 D65EX, PX, WX-15E0