Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — TESTING AND ADJUSTING OPERATOR CAB

30 Testing and adjusting SEN00585-00 3. Testing door lock Close the door and check the relationship between the operator cab and door. If there is any fault, repair it. 1) Check of current condition 1] Check the installed height to damper rubber (1). (Check both sides, 2 pieces on each.) Stick adhesive tape [1], etc. to the contact surface of damper rubber (1) and open and close the door 2 – 3 times. Then, check the contact sur- face of adhesive tape [1] against the operator cab. Normal: When the door is closed, the damper rubber comes in contact lightly. Abnormal:

When the door is closed, the damper rubber does not come in contact or comes in contact so strongly that adhesive tape is removed. 2) Adjusting 1] Adjusting height of damper rubber q Loosen the mounting bolts of damper rubber (1). q You can remove and install the shims without removing the mounting bolts. 2] Check the relationship between the door latch and striker (on both sides). q Increase or decrease of shims (5) under damper rubber (1) to adjust the height of damper rub- ber (1) properly. q Close door (2) and check the engaging condition of latch (3) and striker (4). q Normal: Error of ( a ) must be 0.5 mm or less.

q Check deviation ( a ) of latch cen- ter ( y ) and striker center ( x ) from each other from the direction of ( A ). D65EX, PX, WX-15E0 65