SEN00585-00 30 Testing and adjusting Testing and adjusting operator cab 1 Check after installing cab assembly 1. Measuring pressure in cab q Criteria: Measured value X 58.9 Pa {6 mmH 2 O} q Engine speed: High idle q Fan speed: 100% mode (See the User adjustment mode of the monitor panel) q Fan switch of air conditioner: High q External and internal air changeover switch of air conditioner: Fresh air position a If the measured value is lower than the standard value, check the seals of the holes for wiring harnesses and optional parts in the cab. 1) A simple method of measuring the internal pressure is as follows. 1] Prepare a transparent vinyl hose. 2.
Checking sealing performance 1) Close the all openings of the cab. 2) Splash water around the hatched part of the cab at the rate of about 19 l /min for 10 minutes. q At this time, it is not necessary to splash pressurized water. 3) Splash water horizontally from a hose over sealing surface (4). 4) Check around the dashboard carefully. a If water leaks, caulk the leaking part and check again. q Inside diameter: 6 mm, Length: 3,000 mm 2] Secure the inside end of the hose to the top of the back seat with a tape. 3] Remove bolt (1) under the left con- sole box. Pass the other end of the hose through the bolt hole and take it out of inspection cover (2) on the left side of the cab.
4] Seal the hole of bolt (1) with tape (3). 5] Fill the hose with water up to about the half level and bend the hose in the shape of letter U. 6] Set the water level in the vinyl hose out of the cab to that in the cab. 7] Run the engine at high idle and mea- sure water level difference ( c ). [Value ( c ): Pa {mmH 2 O}] a [ a ] side: Inside of cab (Pressurized) a [ b ] side: Out of cab (Atmospheric pressure) 64 D65EX, PX, WX-15E0