Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

30 Testing and adjusting SEN00586-00 3) Contrast of display This mode is to adjust thickness of the liq- uid crystal at the multi-information section. (See Operation and Maintenance Man- ual.) 5) No injection cranking mode This mode is to circulate the engine oil while applying no injection conditions to all engine cylinders before staring engine after an extended machine storage. 1] This mode is selected by operating the information switch. 2] The mode is selected by turning the buzzer cancel switch to the [ U ] posi- tion. 3] In this condition, turn the starting switch to “start” position to apply no injection cranking.

4] The mode is released by moving the starting switch to ON position and turning the buzzer cancel switch to the [ t ] position. 4) Fan 100% mode This function is to control rotation speed of the cooling fan forcedly at approximately 100% of the maximum speed. 1] This mode is selected by operating the information switch. 2] The mode is selected by turning the buzzer cancel switch to the [ U ] posi- tion. 3] The function is effective under this condition and the rotation speed of the cooling fan is controlled to approximately 100% of the maximum speed. a Exiting this mode disables the function.

k Do not continue no injection cracking for more than 20 sec- onds in order to protect the starting motor. k For safety, this mode cannot be operated while the engine is running. a Exiting this mode disables the function. D65EX, PX, WX-15E0 7