Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

30 Testing and adjusting SEN00586-00 [15] 9997 : High idle limit mode [16] 9998 : Gear speed limit mode q This code is used to limit the high idle speed. q This code is used to restrict the shift to the 3rd gear. q The limited speed (0 – 400) is displayed on the lower line. q The usable gear speeds are displayed by bits on the lower line (in the order of the 3rd, 2nd and 1st from the left). q Possible limit range: High idle speed – 1700 rpm q How to use: 1) Select a limit speed by setting information switch (5) in the [>] position or [ 2) Set buzzer cancel switch (4) in the [ U ] position and check that the alarm buzzer sounds.

a If the high idle speed is limited, the engine speed is not raised to the normal high idle level even if the fuel control dial is con- trolled so. a Even if this code is turned off, the setting is effective. q How to use: Restrict or allow the use of the highest gear speed by operating information switch (5) and buzzer cancel switch (4). q [>]: Restricts a shift to 3rd gear speed. q [ Does not restrict shift to 3rd gear speed. q [ U ]:Determine the setting. q Display on lower line [o]: Gear speed is effective. q Display on lower line [ ]: Gear speed is ineffective.

a If the use of a gear speed is restricted, the transmission is not shifted to that gear speed even if the gear shift up switch is operated. a Even if this code is turned off, the setting is effective. q In order to reduce the noise, the high idle speed of this machine is always controlled to stay below 2030 rpm. Therefore, note that the high idle speed may not change according to the speed limit set while using this function. *1: When 50 rpm is inputted as the speed limit, the engine output is restricted although the high idle speed may not seem to change. D65EX, PX, WX-15E0 31