Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

30 Testing and adjusting SEN00586-00 a While the monitored item is held, the letter “H” is displayed at the left end of the lower line. 6) Changing monitored items (Limited func- tion) Once the monitoring screen is selected in step 2), the monitored item can be changed by operating only information switch (5) without inputting the code again. q [>]: Next code q [ a This function is limited to the numbers marked with a in the “Monitoring mode table”. a Note that this operation is not accepted while the parking brake lever is in the “free” position.

5) When operating machine with monitoring display If the parking brake lever is set in the “free” position, gear speed display section (1) returns to the normal display and the machine can be operated normally. a At this time, even if the shift up or shift down switch is pressed with the PCCS lever in the neutral position, the shift cannot be changed. (The displayed number is the code of monitoring mode.) To change the shift, shift the PCCS lever to the “forward” or “reverse” position and press the shift up or shift down switch while the machine is traveling. a To select another screen, return the parking brake lever to the “free” posi- tion temporarily and perform the nec- essary operation.

D65EX, PX, WX-15E0 35