SEN00587-00 30 Testing and adjusting How to start operation of KOMTRAX terminal 1 In the case where the KOMTRAX terminal is ret- rofitted on the machine after the shipment: a Implement the following procedure in the case where the KOMTRAX terminal is retrofitted after shipment of the machine (retrofitted machine) In the case where the KOMTRAX terminal has already been installed at the plant before ship- ment: a Implement the following procedure in the case where the KOMTRAX terminal has already been installed at the plant before shipment (as standard equipment). 1. Sign-up test on the machine side 1) Move the machine to a place with good visibility of upper direction.
2) Open cover (1) of the main control valve at the right side of the operator cab. 1. Notification of model, model number and serial number Notify the model, model number and serial number of the machine to the KOMTRAX oper- ations administrator. 2. Registration of machine The KOMTRAX operations administrator regis- ters the machine using a KOMTRAX client per- sonal computer. a Refer to “Manual for KOMTRAX opera- tions administrator” for the procedure. a Now the terminal is ready for use. 3) Switch the monitor panel display to “Adjust mode“, enter “Setting KOMTRAX specifi- cation“, and enable the KOMTRAX func- tion. q Adjust code: 0021 q Specification:
ACTIVE 4) Switch the monitor panel display to “Moni- toring mode” and enter “KOMTRAX LED display”. q Monitoring code: 20300 a Refer to “Special functions of monitor panel (EMMS)” for the operating method. 5) Disconnect ACC connector (2), and move on to the next step after confirming that more than 5 seconds have passed since the disconnection. q ACC connector (2): ACF (female) and ACM (male) 20 D65EX, PX, WX-15E0