SEN00589-00 40 Troubleshooting Failure code [CA155] Charge temperature too high and engine speed derated: Exceeded upper control limit of temperature 1 54 D65EX, PX, WX-15E0 Action code Failure code Failure symptom Charge air temperature too high and engine speed derated: Exceeded upper control limit of temperature (Engine controller system) CALL E03 CA155 Failure content • The temperature signal of boost pressure and temperature sensor exceeds upper control limit tem- perature. Controller's action • Operates with limited output. Symptoms that appears on machine • Engine output is reduced. • Engine stops. General information • The boost temperature can be checked in monitoring function.
(Code: 18500 Boost temperature) • Duplication of failure code: Start the engine. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Degradation of cooling per- formance of aftercooler The degradation of aftercooler cooling performance is suspected. Directly check the following points: • Looseness and damage of fun belt • Insufficient cooling air amount • Clogging of aftercooler fin 2 Abnormal rise in turbo- charger outlet temperature The abnormal rise in turbocharger outlet temperature is suspected. Directly check the related parts.
3 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 2. (Internal failure which cannot be diagnosed)