Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA271] IMV/PCV1 SHORT CIRCUIT: SHORT CIRCUIT

SEN00589-00 40 Troubleshooting Failure code [CA271] IMV/PCV1 short circuit: Short circuit 1 66 D65EX, PX, WX-15E0 Action code Failure code Failure symptom IMV/PCV1 short circuit: Short circuit (Engine controller system) CALL E03 CA271 Failure content • Short circuit has been detected at drive circuit of supply pump actuator. Controller's action • No particular action Symptoms that appears on machine • Engine speed does not increase from low idle. • Engine output is reduced. • Fuel pressure of common rail increases above command value. General information • Duplication of failure code: turn ON the starting switch.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective supply pump actu- ator aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF. C17 (male) Resistance Between (1) – chassis ground Min. 100 kz 2 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF. Between ground and wiring harness between CE01 (female) (2) – C17 (female) (1) Resis- tance Min. 100 kz 3 Harness short (Harness internal short) aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF.

Between CE01 (female) (2) – CE01 (female) all pins (With all connectors in the harness disconnected) Resis- tance Min. 100 kz 4 Defective wiring harness connector The connections among inlet metering valve – engine harness – engine controller are suspected to be defective. Visually check it. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 5 Defect in other locations than engine controller aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF. CE01 (female) Resistance Between (2) – chassis ground Min.

100 kz 6 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 5. (Internal failure which cannot be diagnosed)