Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA449] COMMON RAIL PRESSURE TOO HIGH (2): EXCESSIVELY HIGH PRESSURE TROUBLE OCCURRED

40 Troubleshooting SEN00590-00 D65EX, PX, WX-15E0 33 Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 5 Defective common rail pres- sure sensor aPrepare with starting switch ON and diagnose with starting switch ON. Monitoring code (Monitor panel) Monitoring information 36400 Common rail pressure When engine is stopped 0 ± 0.39 MPa {0 ± 4 kg/cm2} 6 Defective O-ring for supply pump actuator aInspect directly if supply pump actuator O-ring is not damaged. 7 Defective supply pump actu- ator aPrepare with starting switch OFF and diagnose with starting switch ON.

Monitoring code (Monitor panel) Monitoring information 36400 Common rail pressure When engine is stopped 0 ± 0.39 MPa {0 ± 4 kg/cm2} aPrepare with starting switch OFF, then start the engine to diag- nose. • Measure after idling for at least 1 minute. Monitoring code (Monitor panel) Monitoring information 36400 Common rail pressure At low idle 1.96 MPa {20 kg/cm2} 8 Defective wiring harness connector Problem is possibly in the common rail fuel pressure sensor con- nector or supply pump actuator, so inspect them directly. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded.

• Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 9 Defective engine controller ground harness aPrepare with starting switch OFF and diagnose with starting switch still OFF. CE03 Resistance Between (1), (2) – chassis ground Max. 10 z 10 Defective supply pump Supply pump is possibly defective if no problem is found in causes 1 – 9.