Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA553] COMMON RAIL PRESSURE TOO HIGH (1): EXCESSIVELY HIGH PRESSURE DETECTED

40 Troubleshooting SEN00590-00 Failure code [CA553] Common rail pressure too high (1): Excessively high pressure detected 1 D65EX, PX, WX-15E0 41 Action code Failure code Symptom of failure Common rail pressure high trouble (1): Excessively high pressure trouble occurred (Engine controller system) CALL E03 CA553 Failure content • Excessively high pressure trouble (1) has occurred in the common rail circuit. Controller's action • No particular action Symptoms that appears on machine • Engine noise becomes louder at no or light load. • Engine output is reduced. General information • Common rail pressure can be checked with the monitoring function. (Code:

36400 Common rail pressure) • Duplication of failure code: Start the engine. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective related circuits Check the failure codes that are displayed at the same time. If any other codes are displayed, carry out troubleshooting for those codes. 2 Defective connection of the ground terminal Defective connection of the ground terminal is suspected. Check the following terminals directly:

• Ground terminal of the machine body (negative terminal of the battery) • Ground terminal of the engine • Ground terminal of the engine controller • Ground terminal of the starting motor 3 Damaged O-ring of supply pump actuator Since a damage of O ring of supply pump actuator is suspected, visually check the O-ring.