40 Troubleshooting SEN00590-00 D65EX, PX, WX-15E0 43 Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 4 Defective supply pump aAs for testing return amount of supply pump, see testing and adjusting “Testing fuel return and leak amount”. Amount of supply pump return When cranking (When engine cannot start) Max. 200 cc/30 sec. At low idle (When engine can be started) Max. 300 cc/30 sec. 5 Defective pressure limiter aAs for testing an amount of pressure limiter leak, see testing and adjusting “Testing fuel return and leak amount”. Pressure limiter leak amount At low idle Max. 30 drops/min.
6 Defective plunger of supply pump aRemove supply pump head and visually inspect the plunger for damage. 7 Air in the low pressure circuit Since a residual air in a low-pressure circuit is suspected, so inspect directly according to the following procedure. 1)Remove pressure inspection plug (outlet side) of fuel main filter. 2)Operate feed pump of fuel pre-filter. 3)Check the leakage of fuel and air from pressure inspection plug. • If this error occurs during the air bleeding operation after the fuel filter replacement, air is possibly remaining in the fuel circuit, so continue to run the engine at low idle for approximately 3 min- utes.
When air bleeding is complete, engine revolutions become stable and the error display disappears.