SEN00590-00 40 Troubleshooting Failure code [CA2185] Decelerator pedal sensor power source too high: Excessively high voltage detected 1 Circuit diagram related to decelerator pedal 54 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Decelerator pedal sensor power source too high: Excessively high voltage detected (Engine controller system) CALL E03 CA2185 • Failure content Excessively high voltage (Min. 5.25 V) is detected in the circuit of decelerator pedal sensor power source. • Controller's action • Operates with the fixed value that is same as the value just before the abnormality is detected, if abnormality occurs with the starting switch in the ON position.
If the starting switch is turned to the ON position in the same abnormal condition, the controller oper- ates with 100% value. Symptoms that appears • on machine Engine speed cannot be controlled by decelerator pedal. General • information Duplication of failure code: turn ON the starting switch. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting Harness short 1 (Harness internal short) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between CE02 (female) (22) – all pins of CE02 (female) (with DCL disconnected) Resis- tance Min.
100 kz Wiring harness between CE02 (female) (9) – DCL (female) (B) and wiring harness between CE02 (female) (22) – DCL (female) (A) Resis- tance Min. 100 kz Defective wiring harness 2 connector Since the connections among decelerator pedal – body harness – engine controller are suspected to be defective, visually check them. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 3 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 2. (Since this is an internal defect, it cannot be diag- nosed.)