Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA2265] ELECTRIC LIFT PUMP DISCONNECTION: DISCONNECTION

SEN00590-00 40 Troubleshooting Failure code [CA2265] Electric lift pump disconnection: Disconnection 1 58 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Electric lift pump disconnection: Disconnection CALL E03 CA2265 Failure content • Disconnection is detected in the drive circuit of electric lift pump actuator. Controller's action • Takes no paticular action. Symptoms that appears on machine • Engine is hard to start. General information • Duplication of failure code: turn ON the starting switch.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective electric lift pump (Internal disconnection and short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. C18 (male) Resistance Between (1) – (2) Max. 20 z 2 Disconnection in wiring har- ness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CE01 (female) (1) – C18 (female) (1) Resis- tance Max. 10 z Wiring harness between CE01 (female) (11) – C18 (female) (2) Resis- tance Max.

10 z 3 Hot short of wiring harness (a contact with 12 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between CE01 (female) (1) – C18 (female) (1) Voltage Max. 6 V 4 Harness short (Harness internal short) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between CE01 (female) (1) – CE01 (female) all pins (All connectors in the harness disconnected) Resis- tance Min. 100 kz 5 Defective wiring harness connector The connections among lift pump valve – engine harness – engine controller are suspected to be defective.

• Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 6 Defect in other locations than engine controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. CE01 (female) Resistance Between (1) – (11) Max. 20 z 7 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 6. (Since this is an internal defect, it cannot be diagnosed.)