SEN00590-00 40 Troubleshooting Failure code [CA2249] Loss of pressure feed from supply pump (2): Loss of pressure feed detected 1 56 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Loss of pressure feed from supply pump (2): Loss of pressure feed detected (Engine controller system) CALL E03 CA2249 Failure content • Loss of pressure feed (2) occurred in the common rail circuit. Controller's action • Operates with limited output. Symptoms that appears on machine • Engine is hard to start. • Exhaust gas color becomes black. • Output decreases. General information • Common rail pressure can be checked with the monitoring function. (Code:
36400 Common rail pressure) • Duplication of failure code: Start the engine. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Carry out troubleshooting of [CA559].