SEN00591-00 40 Troubleshooting Failure code [DAQ1KK] [DB31KK] Main power source of steering and transmission controller: Power source voltage drop and input 1 20 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Main power supply of steering and transmission controller: Power source voltage drop and input (Steering and transmission controller system) CALL E04 DAQ1KK DB31KK Failure content • Power source voltage of steering and transmission controller is less than 17 V. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Limits operation of engine and transmission. Symptoms that appears on machine • Monitor panel may not display normally.
• Relay and solenoid may not drive and therefore, system may not operate normally. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, it becomes impossible to travel. General information • Both of DAQ1KK and DB31KK are displayed. • Battery charge condition (voltage) can be checked in monitoring mode. (Code 03200: Battery voltage) • Duplication of failure code: turn ON the starting switch. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective fuse FS2-7 If fuse FS2-7 is blown, circuit probably has short circuiting with ground.
2 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST3 (female) (1) (11) – FS2-7 Resis- tance Max. 1 z Wiring harness between FS2-3 – battery relay H terminal Resis- tance Max. 1 z Wiring harness between ST3 (female) (21) (31) (32) (33) – ground Resis- tance Max. 1 z 3 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST3 (female) (1) (11) – FS2-7 with ground Resis- tance Min.
1 Mz Wiring harness between FS2-3 – battery relay H terminal with ground Resis- tance Min. 1 Mz 4 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST3 Voltage Between (1) (11) – (21) (31) (32) (33) 20 – 30 V