Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — COOLING FAN PUMP

10 Structure, function and maintenance standard SEN00281-01 Operation 1. Operation of pump q When center line (X) of rocker cam (4) is the same as the axial direction of cylinder block (7) [swash plate angle = 0], the difference between volumes (E) and (F) inside cylinder block (7) is 0, so pump does not suck and dis- charge, and no pumping is carried out. [The swash plate angle is not set to 0 actually, how- ever.] q Cylinder block (7) rotates together with shaft (1), and shoe (5) slides on flat surface (A). At this time, rocker cam (4) tilts around ball (11). As a result, angle ( α ) between center line (X) of rocker cam (4) and the axis of cylinder block (7) changes.

( α ) is called the swash plate angle. q Swash plate angle ( α ) and the pump discharge amount is in relation of proportion. q If angle ( α ) is made between center line (X) of rocker cam (4) and the axis of cylinder block (7), flat surface (A) works as a cam for shoe (5). q Accordingly, piston (6) slides inside cylinder block (7) and a difference is made between volumes (E) and (F) in cylinder block (7). As a result, each piston (6) sucks and discharges oil by (F) – (E). q In other words, cylinder block (7) rotates, and the volume of chamber (E) becomes smaller, so pressurized oil is discharged during this process.

At the same time, the volume of chamber (F) becomes larger and the oil is sucked in this process. [In the figure, chamber (F) is at the end of the suction stroke and chamber (E) is at the end of the discharge stroke.] D65EX, PX, WX-15E0 7