Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DK30KX] STEERING POTENTIOMETER: INPUT SIGNAL IS OUT OF NORMAL RANGE

SEN00591-00 40 Troubleshooting Failure code [DK30KX] Steering potentiometer: Input signal is out of normal range 1 64 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Steering potentiometer: Input signal is out of normal range (Steering and transmission controller system) CALL E04 DK30KX Failure content • Either failure code [DK30KA] or [DK30KB] and either failure code [DK31KA] or [DK31KB] occurred at the same time at steering potentiometer systems 1 and 2. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Limits operation of engine, transmission and brake.

Symptoms that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, it becomes impossible to travel. General information • Input status (voltage) from steering potentiometer can be checked in monitoring mode. (Code 50300: Steering potentiometer 1 voltage) (Code 50301: Steering potentiometer 2 voltage) • Method of reproducing failure code: Turn starting switch ON + (Shift PCCS lever (steering)) Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting Carry out troubleshooting for failure code [DK30KA] [DK30KB] [DK31KA] [DK31KB]