Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DK55KX] FORWARD-REVERSE POTENTIOMETER: INPUT SIGNAL IS OUT OF NORMAL RANGE

SEN00591-00 40 Troubleshooting Failure code [DK55KX] Forward-reverse potentiometer: Input signal is out of normal range 1 72 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Forward-reverse potentiometer: Input signal is out of normal range (Steering and transmission controller system) CALL E04 DK55KX Failure content • Either failure code [DK56KA] or [DK56KB] and either failure code [DK57KA] or [DK57KB] occurred at the same time at forward-reverse potentiometer systems 1 and 2. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Limits operation of engine and transmission.

Symptoms that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, it becomes impossible to travel. General information • Input status (voltage) from forward-reverse potentiometer can be checked in monitoring mode. (Code 50200: Forward-reverse potentiometer 1 voltage) (Code 50201: Forward-reverse potentiometer 2 voltage) • Method of reproducing failure code: Turn starting switch ON + (Shift PCCS lever (forward-reverse) Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting Carry out troubleshooting for failure code [DK56KA] [DK56KB] [DK57KA] [DK57KB]