Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DK55KZ] FORWARD-REVERSE POTENTIOMETER: DISCONNECTION OF SHORT CIRCUIT (DOUBLE FAILURE)

40 Troubleshooting SEN00591-00 Failure code [DK55KZ] Forward-reverse potentiometer: Disconnection or short circuit (Double failure) 1 D65EX, PX, WX-15E0 73 Action code Failure code Symptom of failure Forward-reverse potentiometer: Disconnection or short circuit (Double failure) (Steering and transmission controller system) CALL E04 DK55KZ Failure content • At forward-reverse potentiometer systems 1 and 2, when starting switch was turned ON, only either of them showed abnormality, and later either failure code [DK56KA] or [DK56KB] and either failure code [DK57KA] or [DK57KB] occurred at the same time. Controller's action • Flashes warning lamp and turns on alarm buzzer.

• Limits operation of engine and transmission. Symptoms that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, it becomes impossible to travel. General information • Input status (voltage) from forward-reverse potentiometer can be checked in monitoring mode. (Code 50200: Forward-reverse potentiometer 1 voltage) (Code 50201: Forward-reverse potentiometer 2 voltage) • Method of reproducing failure code:

Turn starting switch ON + (shift PCCS lever (forward-reverse)) Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting Carry out troubleshooting for failure code [DK56KA] [DK56KB] [DK57KA] [DK57KB]