Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DK55L8] FORWARD-REVERSE POTENTIOMETER: INCONSISTENT ANALOG SIGNAL

SEN00591-00 40 Troubleshooting Failure code [DK55L8] Forward-reverse potentiometer: Inconsistent analog signal 1 74 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Forward-reverse potentiometer: Inconsistent analog signal (Steering and transmission controller system) CALL E03 DK55L8 Failure content • Total signal voltage of forward-reverse potentiometer systems 1 and 2 is less than 4.41 V or more than 5.59 V. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Continues to keep it under control with the normal signal of either forward-reverse potentiometer sys- tem 1 or 2. • Limits operation of engine and transmission.

Symptoms that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. General information • Input status (voltage) from forward-reverse potentiometer can be checked in monitoring mode. (Code 50200: Forward-reverse potentiometer 1 voltage) (Code 50201: Forward-reverse potentiometer 2 voltage) • Method of reproducing failure code: Turn starting switch ON + (Shift PCCS lever (forward-reverse)) Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting Carry out troubleshooting for failure code [DK56KA] [DK56KB] [DK57KA] [DK57KB]