Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DKH1KA] [DKH1KX] PITCH ANGLE SENSOR: SHORT CIRCUIT

40 Troubleshooting SEN00592-00 Troubleshooting by failure code (Display of code), Part 4 1 Failure code [DKH1KA] [DKH1KX] Pitch angle sensor: Short circuit 1 Circuit diagram related to pitch angle sensor D65EX, PX, WX-15E0 3 Action code Failure code Symptom of failure Pitch angle sensor: Short circuit (Steering and transmission controller system) CALL E03 DKH1KA DKH1KX Failure conte nt • Signal voltage of pitch angle sensor is above 4.85 V. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Cannot recognize pitch angle. • Limits operation of engine and transmission. Symptoms th appears on machine at • Excessive gear shift shock is felt on a slope.

• Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. General information • Both DKH1KA and DKH1KX are displayed • Input state (voltage) from pitch angle sensor can be checked in monitoring mode. (Code 60100: Voltage of pitch angle sensor) • Duplication of failure code: turn ON the starting switch.

Possible causes and th standard value when norma Cause Defective sensor 24 V power 1 supply circuit Defective pitch angle sensor 2 (internal defect) e s l Hot short of wiring harness 3 (a contact with 24 V circuit) Defective steering and 4 transmission controller Standard value when normal and remarks for troubleshooting ective sensor 24 V power ply circuit Check if failure code [DAQ6KK] or [DB36KK] is displayed. If it is displayed, carry out troubleshooting for it first. ective pitch angle sensor rnal defect) aPrepare with starting switch OFF and diagnose with starting switch ON.

PT1 Voltage Between (B) – (A) 0.15 – 4.85 V short of wiring harness ontact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between ST1 (female) (8) – PT1 (female) (B) Voltage Max. 1 V ective steering and smission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST1 Voltage Between (8) – (21) 0.15 – 4.85 V