Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DLT3KA] TRANSMISSION OUTPUT SPEED SENSOR: DISCONNECTION

SEN00592-00 40 Troubleshooting Failure code [DLT3KA] Transmission output speed sensor: Disconnection 1 Circuit diagram related to transmission output speed sensor 6 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Transmission output speed sensor: Disconnection (Steering and transmission controller system) E01 DLT3KA Failure conte nt • Signal is not input from transmission output speed sensor. Controller' action s • Assumes that transmission output speed is 0 rpm. Symptoms th appears on machin at • Transmission speed cannot be monitored. • Traction force cannot be calculated.

e • Automatic shift-down does not function properly General information • Transmission output speed can be checked in monitoring mode. (Code 31400: Transmission speed) • Duplication of failure code: Start engine and travel machine actually.

Possible causes and t standard valu when norm Cause Defective transmission 1 output speed sensor (internal disconnection) Disconnection in wiring harness 2 (Disconnection or defective contact of connectors) he es al Hot short of wiring harness 3 (a contact with 24 V circuit) Defective steering and 4 transmission controller Standard value when normal and remarks for troubleshooting Defective transmission output speed sensor (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF.

TM1 (male) Resistance Between (1) – (2) 400 – 1,000 z Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST2 (female) (30) – TM1 (female) (1) Resis- tance Max. 1 z Wiring harness between ST2 (female) (29) – TM1 (female) (2) Resis- tance Max. 1 z Hot short of wiring harness (a contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between ST2 (female) (30) – TM1 (female) (1) Voltage Max.

1 V Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. ST2 (female) Resistance Between (30) – (29) 400 – 1,000 z Between (30) – chassis ground Min. 1 Mz