SEN00592-00 40 Troubleshooting Failure code [DW5AKB] Pitch control solenoid: Short circuit 1 Circuit diagram related to pitch control solenoid 10 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Pitch control solenoid: short circuit (Steering and transmission controller system) E02 DW5AKB Failure conten t • Abnormal current flowed when power is outputted to pitch control solenoid circuit. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Stops output to pitch control solenoid circuit. Symptoms tha appears on machine t • Pitch control is not available. General information • Output state (ON/OFF) to pitch control solenoid can be checked in monitoring mode.
(Code 70304: Work equipment-related controller output signal) • Duplication of failure code: Turn starting switch ON and operate pitch control switch. Possible causes and th standard value when normal Cause Defective pitch control solenoid 1 (Internal short circuit) Harness short 2 (Contact with ground circuit) e s Harness short 3 (Harness internal short) Defective steering and 4 transmission controller Standard value when normal and remarks for troubleshooting aPrepare with starting switch OFF and diagnose with starting switch still OFF. 52 (male) Resistance Between (1) – (2) 20 – 30 z Between (1) – chassis ground Min.
1 Mz aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between ST3 (female) (17) – 52 (female) (1) Resis- tance Min. 1 Mz aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harnesses between ST3 (female) (17) – 52 (female) (1) and between ST3 (female) (3) – (52) (female) (2) Resis- tance Min. 1 Mz aPrepare with starting switch OFF and diagnose with starting switch still OFF. ST3 Resistance Between (17) – (3) 20 – 30 z Between (17) – chassis ground Min. 1 Mz