Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DW7BKA] FAN REVERSE SOLENOID: DISCONNECTION

SEN00592-00 40 Troubleshooting Failure code [DW7BKA] Fan reverse solenoid: Disconnection 1 Circuit diagram related to fan reverse solenoid 12 D65EX, PX, WX-15E0 Action code Failure c ode Symptom of failure A Fan reverse solenoid: Disconnection (Steering and transmission controller system) E01 DW7BK Failure content • Current does not flow when power is output to fan reverse solenoid circuit. Controller's action • Stops outputting power to fan reverse solenoid circuit. Symptoms that appears on machine • The fan reversing function cannot be used. General information • Output state (ON/OFF) to fan reverse solenoid can be checked in monitoring mode. (Code 40914:

Steering-related controller output signal) • Duplication of failure code: Turn starting switch ON and operate cleaning. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting Defective 1 (Internal fan reverse solenoid disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF. FAR (male) Resistance Between (1) – (2) 34 – 44 z Disconnec 2 (Disconn contact o tion in wiring harness ection or defective f connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST3 (female) (18) FAR (female) (1) – Resis- tance Max.

1 z Wiring harness between ST3 (female) (13) FAR (female) (2) – Resis- tance Max. 1 z Hot short 3 (a contac of wiring harness t with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness betwee ST3 (female) (18) – FAR (female) (1) n Voltage Max. 1 V Defective 4 transmiss steering and ion controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. ST3 (female) Resistance Between (18) – (13) 34 – 44 z