40 Troubleshooting SEN00592-00 Failure code [DW7BKB] Fan reverse solenoid: Short circuit 1 Circuit diagram related to fan reverse solenoid D65EX, PX, WX-15E0 13 Action code Failure c ode Symptom of failure B Fan reverse solenoid: Short circuit (Steering and transmission controller system) E01 DW7BK Failure content • Current flowed when power is output to fan reverse solenoid circuit. Controller's action • Stops outputting power to fan reverse solenoid circuit. Symptoms that appears on machine • The fan reversing function cannot be used. General information • Output state (ON/OFF) to fan reverse solenoid can be checked in monitoring mode. (Code 40914:
Steering-related controller output signal) • Duplication of failure code: Turn starting switch ON and operate cleaning. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting Defective 1 (Internal fan reverse solenoid short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. FAR (male) Resistance Between (1) – (2) 34 – 44 z Between (1) – chassis ground Min. 1 Mz Defective 2 (Contact harness grounding with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness betwee ST3 (female) (18) – FAR (female) (1) n Resis- tance Min.
1 Mz Harness 3 (Harness short internal short) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harnesses between ST3 (female) (18) FAR (female) (1) and between ST3 (female) (13) – FAR (female) (2) – Resis- tance Min. 1 Mz Defective 4 transmiss steering and ion controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. ST3 (female) Resistance Between (18) – (13) 34 – 44 z Between (18) – chassis ground Min. 1 Mz