SEN00592-00 40 Troubleshooting Failure code [DWN1KA] HSS EPC solenoid right: Disconnection 1 Circuit diagram related to HSS EPC solenoid right 14 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure HSS EPC solenoid right: Disconnection (Steering and transmission controller system) CALL E03 DWN1KA Failure content • Current does not flow when power is output to HSS EPC solenoid right circuit. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Stops outputting to HSS EPC solenoid right circuit. • Limits operation of engine and transmission. Symptoms that appears on machine • Can not turn to the right.
• Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. General information • Output state (current) to HSS EPS solenoid right can be checked in monitoring mode. (Code 50603: Right HSS solenoid output current value) • Duplication of failure code: Turn starting switch ON and operate PCCS lever (for steering to right). Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective HSS EPC solenoid right (Internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF.
HSB (male) Resistance Between (1) – (2) 5 – 15 z 2 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST3 (female) (35) – HSB (female) (1) Resis tance - Max. 1 z Wiring harness between ST3 (female) (3) – HSB (female) (2) Resis tance - Max. 1 z 3 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. ST3 (female) Resistance Between (35) – (3) 5 – 15 z