SEN00592-00 40 Troubleshooting Failure code [DWN5KY] Fan pump TVC solenoid: Short circuit in power source line 1 Circuit diagram related to fan pump TVC solenoid 22 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Fan pump solenoid: Short circuit to power source line (Steering and transmission controller system) E02 DWN5KY Failure con tent • Current flows constantly to fan pump TVC solenoid circuit. Controlle action r's • Flashes warning lamp and turns on alarm buzzer. • Stops outputting power to fan pump TVC solenoid circuit. Symptoms appear on machi that • Fan speed is kept at minimum level. s • Overheat easily.
ne Genera informati • Output state (current) to fan pump TVC solenoid can be checked in monitoring mode. l (Code 31623, 31624: Cooling fan solenoid output current) on • Duplication of failure code: turn ON the starting switch. Possibl causes and standard va when nor Cause Defective fan pump solenoid 1 (Internal disconnection and short circuit) e the Hot short of wiring harness 2 lues (a contact with 24 V circuit) mal Defective steering and 3 transmission controller Standard value when normal and remarks for troubleshooting Defective fan pump solenoid (Internal disconnection and short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF.
FAC (male) Resistance Between (1) – (2) 5 – 15 z Hot short of wiring harness (a contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between ST3 (female) (36) – FAC (female) (1) Voltage M ax. 1 V Defective steering and transmission controller aPrepare with starting switch OFF and start the engine to diag- nose. ST3 Fan speed Voltage Between (36) – (23) Minimum speed Maximum speed 5 – 15 V Max. 5 V