SEN00592-00 40 Troubleshooting Failure code [DXH6KA] 3rd clutch ECMV: Disconnection 1 Circuit diagram related to transmission 3rd clutch ECMV 32 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure 3rd clutch ECMV: Disconnection (Steering and transmission controller system) CALL E 03 DXH6KA Failure co ntent • Current does not flow when power is output to transmission 3rd clutch solenoid circuit. Controlle action • Flashes warning lamp and turns on alarm buzzer. r's • Stops outputting to transmission 3rd clutch solenoid circuit. • Limits operation of engine and transmission. Symptoms appear on mach that • The auto shift down function does not work.
s • Once machine is stopped, engine speed is limited to medium (half). ine • Once machine is stopped, travel is limited to F1 and R1. Genera informati • Output state (current) to 3rd clutch solenoid can be checked in monitoring mode. l • (Code 31604, 31614: 3rd clutch ECMV output current value) on • Duplication of failure code:
Engine start + F3 or R3 travel Possibl causes an standard va when nor Cause Defective 3rd clutch ECMV 1 (internal disconnection) e d the Disconnection in wiring harness lues 2 (Disconnection or defective mal contact of connectors) Defective steering and 3 transmission controller Standard value when normal and remarks for troubleshooting Defective 3rd clutch ECMV (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF. 3SOL (male) Resistance Between (1) – (2) 5 – 25 z Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF.
Wiring harness between ST3 (female) (26) 3SOL (female) (1) – Resis- tance Max. 1 z Wiring harness between ST3 (female) (23) 3SOL (female) (2) – Resis- tance Max. 1 z Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. ST3 (female) Resistance Between (26) – (23) 5 – 25 z