Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-1 THE ENGINE DOES NOT START (THE STARTING MOTOR DOES NOT TURN)

SEN00593-00 40 Troubleshooting E-1 The engine does not start (the starting motor does not turn) 1 6 D65EX, PX, WX-15E0 Symptom of failure • The starting motor does not turn and accordingly the engine does not start. General information • Since the engine start circuit has the neutral safety function, the engine does not start unless the parking lever is in the lock position and the travel lever is in the neutral position. • Since KOMTRAX has the start lock function, the engine cannot be started unless the start lock func- tion is canceled.

• If “the monitor panel does not light up”or “the battery relay does not make operating sound” when turning the starting switch ON, the main electric power supply system is supposed to be defective. So, check the main electric power supply system. • Before starting the troubleshooting, validate that the related failure code is not displayed. (If the failure code [D130KA], [D130KB], [DD14KA], [DD14KB], [DDQ2KA] or [DDQ2KB] is dis- played, conduct troubleshooting for the displayed code first.) Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Insufficient battery capacity Battery voltage Battery specific gravity Min.

25 V Min. 1.26 2 Defective starting switch (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Starting switch Switch position Resistance Between 250(B) and 280(C) OFF Min. 1 Mz START Max. 1 z 3 Defective parking lever switch (internal defect or defective adjustment) aPrepare with starting switch OFF and diagnose with starting switch ON. Monitor panel Parking lever Free position Lock position Other than “P” is displayed. “P” is displayed. 4 Defective neutral safety relay (internal disconnection) aPrepare with starting switch OFF and start the engine to diag- nose.

If the engine starts in accordance with the engine starting operation after the neutral safety relay (NSF) is replaced with another one while the starting switch is set to OFF, the neutral safety relay is defective. 5 Defective alternator (internal short circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Alternator Voltage Terminal R – ground Max. 12 V 6 Detective starting motor (internal defect) aPrepare with starting switch OFF and start the engine to diag- nose. Starting motor Voltage Electric power supply: between terminal B and ground 20 – 30 V Charge: between ST (2) and ground Max. 12 V Starting:

between ST (1) and ground 20 – 30 V When each voltage of electric power supply, charging, and starting is normal but the starting motor does not rotate, the starting motor is defective.